DIY 1000W Inverter 12V /24V DC to 220VAC with EGS002 (low power frequency transformer)
-The circuit is compact, does not require a High Volt DC circuit like the High Freq type inverter
-Durable/durable in shock loads, especially induction loads (dynamo/motor) because the dynamo starting current/initial current is very high applied to the inverter will be resistant to the first transformer not directly to the MOSFET, in contrast to high freq inverters which will receive direct starting load on the H-bridge MOSFET and there is a vulnerable level if the MOSFET power is smaller / weaker for high-freq type inverters.
-Resistant to high distortion/noise loads, the distortion load has a ripple voltage or very high voltage even though it is only microseconds/milliseconds above the voltage that the MOSFET can experience, but the high ripple voltage will be dampened on the transformer, so it is not directly experienced by MOSFET like the high freq inverter type without a good output filter.
The low freq inverter type has an efficiency range of 70-85% or wider than the high-freq inverter type, which is 90-96%, but if the two inverters are loaded at peak load, the efficiency is almost the same in the 80-85% range.
PCB Layout for DIY 1000W Inverter 12V /24V DC to 220VAC with EGS002 (low power frequency transformer)
Video Assembling and Test DIY 1000W Inverter 12V /24V DC to 220VAC with EGS002 (low power frequency transformer)Download File:
Olá.
ReplyDeletePoderia me dizer se a placa no vídeo não é a mesma do projeto para download gerber file?
Os componentes mostrados não coincidem com os da placa no vídeo
Agradecido
my friend's video, the pcb is just in the trial stage and the one that has been fixed is shared by me. if there is confusion can be asked again.
Delete